Commissioning, Quick commissioning keypad control, Set keypad control – Lenze 8400 User Manual

Page 246

Advertising
background image

Commissioning

Quick commissioning

Keypad control

7

246

EDS84ASC552 EN 9.1

MCTRL: Act. speed val.

C00051

0 rpm

When the Lenze setting is loaded,

the display goes off for a short

time.

When the display goes on again,

the main menu appears.

– The main menu settings can be

defined by the user using codes

C00465 ... C00469.

Press the left function key to go

to the user menu.

4. Set keypad control

EDIT

Select CtrlMode

C00007

Quick commissioning

SAVE

Par1 Quick commissioning

Terminals

Keypad

SAVE

Par1 8400 StateLineC

User - Menu

Logbook

Go to param

Quick commissioning

EDIT

Load Lenze setting

C00002/1

Continue as with commissioning

step 3. Load Lenze setting to

controller:

– ”Quick commissioning” menu

– Keypad

– Load Lenze setting

Use the ”down” navigation key to go

to code C00007 for selecting the

control mode:

Select parameter code 00007 and

parameterise with ”Edit”

Select value ”20”- -> Keypad and

confirm with ”OK”.

5. Enable controller:

– StateLine: Set terminal X4/RFR to HIGH potential (reference: X4/24I).
– HighLine/TopLine: Set terminal X5/RFR to HIGH potential (reference: X5/24I).

6. Vary the motor speed with the keypad or by defining different fixed setpoints:

Keypad

Code

Subcode

Motor speed

EDIT

< ... >

C00728

C00051

SAVE

Par1 Quick commissioning

Terminals

Keypad

C00728

3

CCW rotation:

-199.99 % .... 0 (of C00011)

CW rotation:

0 .... +199.99 % (of C00011)

C00051

-

Display of actual speed

value

ƒ

Please observe:
– the actual speed value: C00051

7. Save the settings with  in the keypad.