Electrical installation – Lenze 8400 User Manual

Page 207

Advertising
background image

Electrical installation

Devices in a power range of 30 ... 45 kW (3/PE AC 400 V)

Terminal assignment of the power connections

6

207

EDS84ASC552 EN 9.1

Motor temperature monitoring

Note!

In the Lenze setting, motor temperature monitoring is activated! In the

delivery status, there is a wire jumper between the terminals X106/T1 and

X106/T2. Before connecting a thermal sensor, remove the wire jumper.

Note!

If the terminal X106 is used, e.g. to connect an external PTC thermistor or a

thermal contact, ensure at least one basic insulation to the motor or mains

potential to not restrict the protective separation of the control terminals.

Terminal X106

Labelling

Description

T1

T2

Motor temperature monitoring with PTC element

(type-A sensor, switching performance acc. to EN 60947-8 for

type-A tripping units) or thermostat

(NC contact).

Lenze setting: activated, error message

Setting in C00585

8400GG016b

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

E84AVxxxxxxx

0.2 ... 1.5

24 ... 16

-

-

2.5 x 0.4

Tip!

For an easy removal of the wire jumper:

1. Cut the wire jumper with side-cutting pliers.

2. Overcome the spring pressure of the terminal with a screwdriver.

3. Remove both wire ends individually.

Advertising
This manual is related to the following products: