Standard devices in the power range 3 ... 22 kW
Assembly without filter in ”standard” technique
5
115
EDS84ASC552 EN 9.1
TopLine
8400GG106i
Fig. 5-21
Device dimensions
h
b
t
h
1
h
2
t
1
t
2
g
1
g
2
g
3
[kW]
[mm]
E84AVTCE3024xXx
3
270
140
214
303
360
201
240
6
11
12
E84AVTCE4024xXx
4
E84AVTCE5524xXx
5.5
E84AVTCE7524xXx
7.5
325
140
214
359
416
201
240
6
11
12
E84AVTCE1134xXx
11
E84AVTCE1534xXx
15
E84AVTCE1834xXx
18.5
350
205
265
359
430
252
291
7
10
13
E84AVTCE2234xXx
22
E84AVTCE3024xBx
3
270
140
234
303
360
221
260
6
11
12
E84AVTCE4024xBx
4
E84AVTCE5524xBx
5.5
E84AVTCE7524xBx
7.5
325
140
234
359
416
221
260
6
11
12
E84AVTCE1134xBx
11
E84AVTCE1534xBx
15
E84AVTCE1834xBx
18.5
350
205
285
359
430
272
311
7
10
13
E84AVTCE2234xBx
22