Technical data, Current characteristics – Lenze 8400 User Manual

Page 70

Advertising
background image

Technical data

Current characteristics

4

70

EDS84ASC552 EN 9.1

Maximum output currents [A]

1)

at a variable switching frequency

U

Lr

= 230V

Type

I

aM0v

I

aMv

E84AVxxx2512

3.4

3.4

E84AVxxx3712

4.8

4.8

E84AVxxx5512

6.0

6.0

E84AVxxx7512

8.0

8.0

E84AVxxx1122

8.3

11.0

E84AVxxx1522

10.5

14.0

E84AVxxx2222

14.3

19.0

Maximum output currents [A]

1)

at a variable switching frequency

U

Lr

= 400V/U

Lr

= 500V

Type

I

aM0v

I

aMv

E84AVxxx3714

2.6

2.6

E84AVxxx5514

3.6

3.6

E84AVxxx7514

4.8

4.8

E84AVxxx1124

4.8

6.4

E84AVxxx1524

5.9

7.8

E84AVxxx2224

8.4

11.2

E84AVxxx3024xxS

11.0

14.6

E84AVxxx3024xx0

11.0

14.6

E84AVxxx4024

14.3

19.0

E84AVxxx5524

19.5

26.0

E84AVxxx7524

24.8

33.0

E84AVxxx1134

35.3

47.0

E84AVxxx1534

48.0

64.0

E84AVxxx1834

58.5

78.0

E84AVxxx2234

70.5

89.3

E84AVxxx3034

88.5

112.1

E84AVxxx3734

108.0

136.8

E84AVxxx4534

133.5

169.1

1)

The shown values apply to the operation with ambient temperatures of up to +45°C for 2/4kHz and up to +40°C for

8/16kHz. For ambient temperatures between +40/45°C and +55°C, a derating from 2.5 %/K to the given values must

be observed.

Advertising
This manual is related to the following products: