EDS84ASC552 EN 9.1

The values of the fuses used may be equal to or fall below the values in the following table:

Branch circuit protection

Fuse [A]

Circuit breaker

Type

with mains

choke

without mains

choke

Type 5kA rms

Type 50kA rms

Rating

E84AVxxx2512

6

6

Schneider Electric:

Multi9 C60

Charact. C

Moeller:

FAZ-C

Charact. C

Siemens:

3RV1742

15 A

E84AVxxx3712

10

10

15 A

E84AVxxx5512

10

10

15 A

E84AVxxx7512

15

15

15 A

E84AVxxx1122

20

20

20 A

E84AVxxx1522

25

25

25 A

E84AVxxx2222

30

30

30 A

E84AVxxx3714

6

6

15 A

E84AVxxx5514

6

6

15 A

E84AVxxx7514

6

6

15 A

E84AVxxx1124

10

10

15 A

E84AVxxx1524

10

10

15 A

E84AVxxx2224

10

10

15 A

E84AVxxx3024xxS

15

15

15 A

E84AVxxx3024xx0

15

15

15 A

E84AVxxx4024

20

20

20 A

E84AVxxx5524

20

20

20 A

E84AVxxx7524

20

25

Siemens:

3RV1742

25 A

E84AVxxx1134

30

40

40 A

E84AVxxx1534

50

-

50 A

E84AVxxx1834

60

60

-

-

-

E84AVxxx2234

60

-

-

E84AVxxx3034

80

-

-

-

-

E84AVxxx3734

100

-

-

-

-

E84AVxxx4534

125

-

-

-

-

Warnings!

For CSA Certification drives are intended to be used with Chokes -

UL Recognized (XPTQ2/8, FOKY2/8) or CSA Certified (XPTQ2, FOKY2), File

Number E103521 or E198787, mounted on the line side of the devices.
The chokes are listed in chapter 4.2 Rated Data and chapter 11.2 Accessories.