Electrical installation – Lenze 8400 User Manual

Page 167

Advertising
background image

Electrical installation

Installation according to EMC (installation of a CE-typical drive system)

Shielding

6

167

EDS84ASC552 EN 9.1

Realisation

PE

PE

PE

M

3~

8
9

PES

1

2
4

7

0

6

5

3

8400SLC024

Fig. 6-2

Wiring in compliance with EMC standards

Mounting plate with electrically conductive surface

Control cables, connect shielding to the upper shield sheet (PES) with a surface as large as

possible

Terminal for motor PE

PE of the motor cable

Shield of the motor cable

Shielded motor cable, low-capacitance
(Core/core 1.5 mm

2

 75 pF/m; from 2.5 mm

2

 100 pF/m; core/shield  150 pF/m)

Shielded PTC cable or thermal contact cable (preferentially installed separately)

Connect cable shields to the lower shield sheet (PES) with a large surface. Preferentially use

metal cable binders from the accessories.

Star or delta connection as indicated on the motor nameplate

EMC cable gland (not included in the scope of supply)