Mechanical installation

Standard devices in a power range of 30 ... 45 kW

Filter mounting in ”standard” technique

5

145

EDS84ASC552 EN 9.1

E84ZESx007

Proceed as follows for installation:
1. Prepare threaded holes on the mounting plate.
2. Equip threaded holes with screws and washers.

– Use 4 screw and washer assemblies or hexagon socket screws with washers.
– Do not fully tighten the screws.

3. Mount the filter onto the prepared mounting plate.

– Only tighten the screws hand-tight.

4. Mount the standard device onto the filter.

– Use 4 screw and washer assemblies or hexagon socket screws with washers.

5. If required, pre-assemble further units.
6. Adjust all units.
7. Screw all units onto the mounting plate.

– Starting torque: 7 Nm (62 lb-in)