Technical data – Lenze 8400 User Manual

Page 31

Advertising
background image

Technical data

General data and operating conditions

4

31

EDS84ASC552 EN 9.1

EMC
Interference emission

cable-guided

EN 61800-3

Up to a shielded motor cable length of 25 m: Category C2

With interference suppression: Category C1

Radiation

Category C2

Immunity to interference (acc. to EN 61800-3 requirements)

Electrostatic discharge

(ESD)

EN 61000-4-2

Air discharge: 8 kV,

Contact discharge to housing: 4 kV

High frequency

cable-guided

EN 61000-4-6

150 kHz ... 80 MHz, 10 V/m 80 % AM (1kHz)

Interference (housing) EN 61000-4-3

80 MHz ... 1000 MHz, 10 V/m 80 % AM (1kHz)

Burst

Power connections

and interfaces

EN 61000-4-4

2 kV/5 kHz

Signal interfaces

EN 61000-4-4

1 kV/5 kHz

Control terminals

EN 61000-4-4

2 kV/5 kHz

Surge (surge voltage)

Power connections

EN 61000-4-5

1.2/50 s,

1 kV phase-phase, 2 kV phase-PE

Control terminals

EN 61000-4-5

1.2/50 s, 1 kV

Operation on public supply

systems

EN 61000-3-2

EN 61000-3-12

The devices are intended for the use in industrial

environments. If they are used on public systems, measures

must be taken to limit the radio interference to be expected.

The machine / system manufacturer is responsible for

compliance with the machine / system requirements!

EN 61000-3-2

< 0.5 kW: With mains choke
0.5 ... 1 kW: With active filter
> 1 kW at a mains current of  16 A: No limit values for

harmonic currents

EN 61000-3-12

Mains current > 16 A: in combination with an assigned mains

choke or mains filter, in case of dimensioning for operation

with rated power.

The requirement for the short-circuit power ratio RSCE  120