C01238 | mck: s-ramp time follower, C01239 | setpoint holding, C01240 | mck: control word – Lenze 8400 User Manual

Page 1005: C01240, C01239, Etting rule, C01238/1, 16 parameter reference

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1005

16

Parameter reference

16.2

Parameter list | C01238

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01238

C01239

C01240

Parameter | Name:

C01238 | MCK: S-ramp time follower

Data type: UNSIGNED_16

Index: 23337

d

= 5B29

h

S-ramp times for position follower

• Setting "0 s" ≡ no rounding

Position follower

Setting range

(min. value | unit | max. value)

0.000

s

10.000

Subcodes

Lenze setting

Info

C01238/1

0.000 s

Pos follower: Sync. S-ramp time

• S-ramp time for the synchronisation speed ramps.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01239 | Setpoint holding

Data type: UNSIGNED_32

Index: 23336

d

= 5B28

h

From version 12.00.00

Setpoint holding for bus runtime compensation

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

32 0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01240 | MCK: Control word

Data type: UNSIGNED_32

Index: 23335

d

= 5B27

h

Bit-coded status of the MCK control word

• The MCK control word is used to control the functions of the Motion Control Kernel.

MCK control word

Display area

(min. hex value | max. hex value)

0x00000000

0xFFFFFFFF

Value is bit-coded:

Info

Bit 0 OpMode_Bit0

Active operating mode - control bit 0

Bit 1 OpMode_Bit1

Active operating mode - control bit 1

Bit 2 OpMode_Bit2

Active operating mode - control bit 2

Bit 3 OpMode_Bit3

Active operating mode - control bit 4

Bit 4 ManJogPos

Control bit for manual jog in positive direction

Bit 5 ManJogNeg

Control bit for manual jog in negative direction

Bit 6 ManExecute2ndSpeed

Control bit for activation of second manual speed

Bit 7 ReleaseLimitSwitch

Control bit for retracting the hardware limit positions

Bit 8 HomStartStop

Control bit for start/stop homing

Bit 9 HomSetPos

Control bit for setting of home position

• "0->1" ≡ sets position setpoint and actual position

value to the home position at the MCK.

• This function is independent of the operating modes.

Bit 10 HomResetPos

Control bit for reset of home position

• "0->1" ≡ resets the information bit for the status

"Home position known" (home position not known).

• The position displays are not influenced by this.