C02879/1, 16 parameter reference – Lenze 8400 User Manual

Page 1070

Advertising
background image

16

Parameter reference

16.2

Parameter list | C02879

1070

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02879

C02994

C02995

C02996

Parameter | Name:

C02879 | Slip calculation from equivalent circuit diagram

Data type: UNSIGNED_16

Index: 21696

d

= 54C0

h

From version 12.00.00

In order to achieve a better speed stability and torque accuracy, the slip calculation can be either derived from the

motor nameplate data (e.g. rated motor speed) or the motor equivalent circuit diagram data (stator resistance, rotor

resistance etc.).
Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 SLVC

Slip calculation for SLVC

Bit 1 SC ASM

Slip calculation for SC

Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved

Subcodes

Lenze setting

Info

C02879/1

0x0000

Slip calculation from equivalent circuit diagram

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02994 | FB xy position

Data type: UNSIGNED_32

Index: 21581

d

= 544D

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C02995 | FB display InputOutput

Data type: UNSIGNED_32

Index: 21580

d

= 544C

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C02996 | FB display InputOutput2

Data type: UNSIGNED_32

Index: 21579

d

= 544B

h

This code is for device-internal use only and must not be written to by the user!