Parameter | Name:

C00222 | L_PCTRL_1: Vp

Data type: INTEGER_16

Index: 24353

d

= 5F21

h

The

L_PCTRL_1

FB: Gain factor Vp for the PID process controller

Setting range

(min. value | unit | max. value)

Lenze setting

0.1

500.0 1.0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00223 | L_PCTRL_1: Tn

Data type: UNSIGNED_16

Index: 24352

d

= 5F20

h

The

L_PCTRL_1

FB: Reset time Tn for the PID process controller

Setting range

(min. value | unit | max. value)

Lenze setting

20

ms

6000 400 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00224 | L_PCTRL_1: Kd

Data type: UNSIGNED_16

Index: 24351

d

= 5F1F

h

The

L_PCTRL_1

FB: Derivative-action coefficient Kd for the PID process controller

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

5.0 0.0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00225 | L_PCTRL_1: MaxLimit

Data type: INTEGER_16

Index: 24350

d

= 5F1E

h

The

L_PCTRL_1

FB: Maximum output value of the PID process controller

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 199.99 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00226 | L_PCTRL_1: MinLimit

Data type: INTEGER_16

Index: 24349

d

= 5F1D

h

The

L_PCTRL_1

FB: Minimum output value of the PID process controller

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 -199.99 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100