3commissioning – Lenze 8400 User Manual

Page 71

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

71

3

Commissioning

3.8

Commissioning of the "Table positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

The Encoder/Feedback system parameterisation dialog will be shown:

3. In the Position encoder selection list field (

C00490

), select "Encoder signal FreqIn12".

4. Set the number of position encoder increments in the Number of encoder increments at

FreqIn12 input field (

C00420/1

).

5. In the Fct. DI 1/2 100kHz list field (

C00115/1

), select "DI1(5)&DI2(6)=FreqIn (2-track)".

• This selection ensures that the digital DI1 and DI2 input terminals are configured as

frequency inputs.

6. Adapt the proportional gain, Kp position controller (

C00115/1

), if necessary. This parameter can

be found on the second page of the dialog and can be reached via the >>> button.

7. Click the Close button to close the parameterisation dialog again.

Related topics:

Digital terminals

( 303)

Using DI1(5) and DI2(6) as frequency inputs

( 307)