3commissioning – Lenze 8400 User Manual

Page 63

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

63

3

Commissioning

3.8

Commissioning of the "Table positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.8

Commissioning of the "Table positioning" technology application

[3-2]

Block diagram for wiring the commissioning example for the "Table positioning" application

Note!

Take all the necessary safety precautions before you carry out the following

commissioning steps and switch the device on!

Safety instructions with regard to commissioning

( 49)

System constellation

X41/DI1

Position encoder connection, track A

X41/DI2

Position encoder connection, track B

X42/DI3

Hardware limit switch connection in positive direction

X42/DI4

Hardware limit switch connection in negative direction

X43/DI5

Profile selection and change of operating mode at the same time:

LOW level: Selection of profile number 1 and "Homing" operating mode

HIGH level: Selection of profile number 3 and "Positioning" operating mode

X43/DI6

Start of profile generation

X70

Diagnostic interface for connecting the USB diagnostic adapter

8400 protec

X61

X6

DIAG

AR A1U GA

X50

24O DI1 DI2 GIO

X41

24O DI3 DI4 GIO

X42

24O DI5 DI6 GIO

X43

U

V W

X70

M

3~

0-Position

20

30

10

-10

-20

-30

40

i

A

B

DI6: PosExecute

DI5: PosProfile