8basic drive functions (mck) – Lenze 8400 User Manual
Page 495
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
495
8
Basic drive functions (MCK)
8.6
Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 8: >_TP
Procedure:
1. Movement in positive direction with start profile data set.
2. Following edge of the touch probe sensor sets home position.
Mode 9: <_TP
Procedure:
1. Movement in negative direction with start profile data set.
2. Following edge of the touch probe sensor sets home position.
Touch probe
Mode 8
>
TP
Offset path
Sequence profile (optional)
Start speed
Profile speed
Lp
Active
Active
Active
Active
Ln
Inactive
Inactive
Active
Active
Touch probe
Mode 9
<
TP
Offset path
Sequence profile (optional)
Start speed
Profile speed
Lp
Inactive
Inactive
Active
Active
Ln
Active
Active
Active
Active
1
0
1
0