Parameter list | C00427

826

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00427

C00428

C00440

Parameter | Name:

C00427 | SSI encoder: Bit rate

Data type: UNSIGNED_8

Index: 24148

d

= 5E54

h

From version 02.00.00

Encoder/feedback system: SSI encoder

Selection list

(Lenze setting printed in bold)

1 100 kbps
2 200 kbps
3 300 kbps
4 400 kbps
5 500 kbps
6 750 kbps
7 1000 kbps

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00428 | SSI encoder: Coding

Data type: UNSIGNED_8

Index: 24147

d

= 5E53

h

From version 02.00.00

Encoder/feedback system: SSI encoder

Selection list

(Lenze setting printed in bold)

0 Binary code
1 Gray code

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00440 | LS_AnalogIn1: PT1 time constant

Data type: UNSIGNED_16

Index: 24135

d

= 5E47

h

PT1 time constant (S-ramp time) for the analog inputs

Analog terminals

Setting range

(min. value | unit | max. value)

0

ms

1000

Subcodes

Lenze setting

Info

C00440/1

10 ms

PT1 rounding AnalogIn1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1