C00427 | ssi encoder: bit rate, C00428 | ssi encoder: coding, C00440 | ls_analogin1: pt1 time constant – Lenze 8400 User Manual
Page 826: Set the bit rate, C00427, C00428, C00440/1, 16 parameter reference
16
Parameter reference
16.2
Parameter list | C00427
826
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00427
C00428
C00440
Parameter | Name:
C00427 | SSI encoder: Bit rate
Data type: UNSIGNED_8
Index: 24148
d
= 5E54
h
From version 02.00.00
Encoder/feedback system: SSI encoder
Selection list
(Lenze setting printed in bold)
1 100 kbps
2 200 kbps
3 300 kbps
4 400 kbps
5 500 kbps
6 750 kbps
7 1000 kbps
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00428 | SSI encoder: Coding
Data type: UNSIGNED_8
Index: 24147
d
= 5E53
h
From version 02.00.00
Encoder/feedback system: SSI encoder
Selection list
(Lenze setting printed in bold)
0 Binary code
1 Gray code
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00440 | LS_AnalogIn1: PT1 time constant
Data type: UNSIGNED_16
Index: 24135
d
= 5E47
h
PT1 time constant (S-ramp time) for the analog inputs
Setting range
(min. value | unit | max. value)
0
ms
1000
Subcodes
Lenze setting
Info
C00440/1
10 ms
PT1 rounding AnalogIn1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1