Xx.0123.00094, Xx.0123.00095, Xx.0123.00096 – Lenze 8400 User Manual

Page 596: Xx.0123.00097, Xx.0123.00093, 9diagnostics & error management

Advertising
background image

9

Diagnostics & error management

9.10

Error messages of the operating system

596

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

ot2: Speed controller output limited [xx.0123.00093]

FC01: Switching frequency reduction [xx.0123.00094]

FC02: Maximum speed for Fchop [xx.0123.00095]

oC14: Direct-axis current controller limitation [xx.0123.00096]

oC15: Cross current controller limitation [xx.0123.00097]

Response (Lenze setting printed in bold)

Setting:

C00567

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The output of the speed controller has reached the

internal limit value. In this status, the speed controller is

not able anymore to correct the system deviation.

• Only during "Closed loop" operation or with vector

control (SLVC).

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Response (Lenze setting printed in bold)

Setting:

C00590

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Load-dependent switching frequency reduction

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Response (Lenze setting printed in bold)

Setting:

C00588

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Maximum speed for chopper frequency has been

reached.

• The maximum speed has been exceeded depending

on the switching frequency.

Select the correct maximum speed as a function of the

switching frequency.

Motor control: Determine speed limits

Response (Lenze setting printed in bold)

Setting:

C00570/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Direct-axis current controller limitation is active.

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Response (Lenze setting printed in bold)

Setting:

C00570/2

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Cross current controller limitation is active.

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

• Check parameter setting of the current controller

with regard to the motor controllers (e.g. reduce Vp).

Motor control