I-1200, 11 canopen option – Lenze 8400 User Manual

Page 685

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

685

11

CANopen option

11.11

Implemented CANopen objects | I-1200

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1200

Identifiers for SDO server channel 1 (basic SDO channel).

• According to DS301 V4.02, the basic SDO channel can neither be changed nor deactivated.

[11-5] Data telegram assignment

Index:

I-1200

Name:

SDO1 server parameter

Subindex

Default setting

Display range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

2

2

2 ro

U8

1: COB-ID client -> server (rx)

node ID + 0x600

0

4294967295 ro

U32

2: COB-ID server -> client (tx)

node ID + 0x580

0

4294967295 ro

U32

Subindex

Meaning

1

Specification of receive identifier

• For SDO server channel 1: node address (C00350) + 0x600

2

Specification of send identifier

• For SDO server channel 1: node address (C00350) + 0x580

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31

Bit 30

Bit 29 ... bit 11

Bit 10 ... bit 0

0

0

Extended identifier*

11-bit identifier

* The extended identifier is not supported. Bit 11 ... bit 29 must be set to "0".