C00097 | rated motor torque, C00098 | device rated current, C00099 | firmware version – Lenze 8400 User Manual

Page 762: C00100 | firmware version, C00099, C00098, Ompare, 16 parameter reference

Advertising
background image

16

Parameter reference

16.2

Parameter list | C00097

762

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00097

C00098

C00099

C00100

Parameter | Name:

C00097 | Rated motor torque

Data type: UNSIGNED_32

Index: 24478

d

= 5F9E

h

Display of the rated motor torque

• The value displayed here is calculated from different parameters, e.g. the maximum current set in

C00022

.

Display range

(min. value | unit | max. value)

0.00

Nm

100000.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00098 | Device rated current

Data type: UNSIGNED_16

Index: 24477

d

= 5F9D

h

Display of the rated inverter current which is defined by the integrated power section.
Display range

(min. value | unit | max. value)

0.0

A

6000.0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00099 | Firmware version

Data type: VISIBLE_STRING

Index: 24476

d

= 5F9C

h

Display of the firmware version of the device as string

Read access  Write access  CINH  PLC-STOP  No transfer  COM  MOT

Character length: 12

Parameter | Name:

C00100 | Firmware version

Data type: UNSIGNED_8

Index: 24475

d

= 5F9B

h

Display of the firmware version of the device, divided into subsections.
Display range

(min. value | unit | max. value)

0

99

Subcodes

Info

C00100/1

Firmware version - main version

C00100/2

Firmware version - subversion

C00100/3

Firmware version - release

C00100/4

Firmware version - build

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising