C01213 | mck: max. traversing distance, C01215 | mck: following error, C01216 | mck: positioning setting – Lenze 8400 User Manual

Page 997: C01244/2, C01215/2, C01216, G in, C01213/1, C01215/1, Ror in

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

997

16

Parameter reference

16.2

Parameter list | C01213

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01213

C01215

C01216

Parameter | Name:

C01213 | MCK: Max. traversing distance

Data type: INTEGER_32

Index: 23362

d

= 5B42

h

Display of current position limits
Display range

(min. value | unit | max. value)

-2147480000

units

2147480000

Subcodes

Info

C01213/1

MCK: Max. traversing distance

• Display of the maximum distance to be traversed

referred to the 32-bit display area (max. 2147483647

increments).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01215 | MCK: Following error

Data type: INTEGER_32

Index: 23360

d

= 5B40

h

Limits for following error monitoring system

Following error monitoring system

Setting range

(min. value | unit | max. value)

0.0000

units

214748.0000

Subcodes

Lenze setting

Info

C01215/1

0.0000 units

MCK: Following error limit 1

• First limit of the maximum following error for

monitoring and response activation.

C01215/2

0.0000 units

MCK: Following error limit 2

• Second limit of the maximum following error for

monitoring and response activation.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01216 | MCK: Positioning setting

Data type: UNSIGNED_8

Index: 23359

d

= 5B3F

h

Positioning

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x01 (decimal: 1)

Value is bit-coded: (= bit set)

Bit 0  PosAbort at PosInit
Bit 1  PosExecute active at PosInit
Bit 2  Reserved
Bit 3  Reserved
Bit 4  ProfilStart at PosInit
Bit 5  Reserved
Bit 6  Reserved
Bit 7  Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising