Xx.0184.08015, Xx.0400.00009, Xx.0400.00016 – Lenze 8400 User Manual

Page 608: Xx.0400.00104, Xx.0400.00105, Xx.0980.00001, 9diagnostics & error management

Advertising
background image

9

Diagnostics & error management

9.10

Error messages of the operating system

608

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Ck13: Error - MCKCtrlInterface function block [xx.0184.08015]

dH09: EEPROM power section [xx.0400.00009]

dH10: Fan failure [xx.0400.00016]

dH68: Adjustment data error CU [xx.0400.00104]

dH69: Adjustment data error BU [xx.0400.00105]

US01: User error 1 [xx.0980.00001]

Response (Lenze setting printed in bold)

Setting:

C00595/13

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: An error in the

L_MckCtrlInterface_1

function

block has occurred.

Check wiring and parameterisation of the

L_MckCtrlInterface_1

function block.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

Setting:

C00566

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device fan has failed.

Possible causes:

• The short-circuit check of the fan connection has

tripped.

• The speed monitoring of the fan has tripped.

• Check the fan for short-circuit.

• Clean the fan.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

Setting:

C00581/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

User error 1 has been tripped via the bSetError1 input of

the

LS_SetError_1

system block.

User-defined.