3 save all parameter sets, Save all parameter sets, 4device control (dctrl) – Lenze 8400 User Manual

Page 102

Advertising
background image

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

102

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.3

Save all parameter sets

If parameter settings are changed in the controller, those changes will be lost after mains switching

of the controller unless the settings have been saved explicitly.
The

C00002/11

= "1: On / start" device command saves the current parameter settings safe against

mains failure to the memory module of the controller.

How to save the parameter settings to the memory module:
Execute the "Save all parameter sets" device command:

C00002/11

= "1: On / start"

The storage process may take a couple of seconds. After the device command has been

called in

C00002/11

, dynamic status information ("Work in progress 20%"  "Work in

progress 40%"  "Work in progress 60%", etc.) is returned.

Tip!

• This device command can also be activated via the

icon in the Toolbar.

• The "

Load Lenze setting

" device command (

C00002/1

= "1: On / start") resets the

parameter settings to the delivery status of the device.

Note!

When the device is switched on, all parameters are automatically loaded from the

memory module to the main memory of the controller.
Observe the following to avoid data inconsistencies which cause errors when the

parameters are loaded from the memory module:
During the storage process:

• Do not switch off the supply voltage!
• Do not remove the memory module from the device!

The controller is currently provided with one data record for all parameters, i.e. every

parameter has a value. Several data records per controller are in preparation.