15 parameter change-over – Lenze 8400 User Manual

Page 722

Advertising
background image

15

Parameter change-over

15.1

Configuring parameter change-over via the »Engineer« parameterisation dialog

722

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Copying values
All the settings of a value set can be copied to another value set.

To copy values, proceed as follows:

1. Click on the Copy values button.

• The Copy values dialog box is displayed:

2. Define the parameter list to be copied via the two upper checkboxes.
3. Select Source and Target.

4. Click on

button in order to copy the values from Source to target.

Importing/exporting the list
For cross-device reuse of the configured WriteParamList, you can click on the Export and Import

buttons to save the parameter selection as an *.epc file and then to re-import the saved *.epc file

into another drive controller 8400.

Advertising