4 drive diagnostics with the »engineer, Drive diagnostics with the »engineer, 9diagnostics & error management – Lenze 8400 User Manual

Page 560

Advertising
background image

9

Diagnostics & error management

9.4

Drive diagnostics with the »Engineer«

560

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.4

Drive diagnostics with the »Engineer«

When an online connection to the controller has been established, the connected controller can be

diagnosed and relevant actual controller states can be displayed in a clearly arranged visualisation

using the »Engineer«:

Button

Function

Display details of the status determining error.

Display details of the current error.

Display all active sources of a controller inhibit.

Display all active sources of a quick stop.

Monitoring...

Configure the Monitoring

.

( 573)

Device status...

Display the internal state machine including the current device status.

Drive control...

Display the bit assignment of the following control-related words:

• MCI control word (

C00136/1

)

• CAN control word (

C00136/2

)

• Cause of controller inhibit (

C00158

)

• Cause of quick stop (

C00159

)

• Status word (

C00150

)

• Status word 2 (

C00155

)

Device information...

Display identification data, e.g. firmware information or serial number of individual

controller components.

Reset error

Acknowledge error message (if the error cause has been eliminated).

Logbook...

Display the Logbook

of the controller.

( 566)