Introduction: Parameterising the controller

2.4

Device access protection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Activating device personalisation
The device personalisation is activated by setting a binding ID.

How to set a binding ID:

1. Enter the desired binding ID in

C00505/2

.

• The binding ID must have a length of 4 ... 16 characters.
• The binding ID may consist of any character. However, this is not sensible.

Recommended characters are: lower case letters (a - z), upper case letters (A - Z) and

digits (0 - 9).

2. Execute "Set binding ID" device command

C00002/29

= "1: On / start"

• After successful execution, status ON is displayed in

C00505/2

.

C00002/29

Set binding ID

Activating device personalisation

0: Off / ready

C00002/30

Delete binding ID

Deactivating the device personalisation/changing the binding ID

0: Off / ready

Status displays

C00003

Status of the last device command

-

C00507/1

Password protection - all communication channels

• Bit coded display of the active protective functions:

-

Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection

Bit 3 ... 14 Reserved

Bit 16 Memory module binding on

Parameter

Info

Lenze setting

Highlighted in grey = display parameter