I/O terminals

6.1

Digital terminals

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Counting behaviour
The following temporal characteristic shows the counting process depending on the signals of the

interfaces described before:

[6-1]

Transient characteristic of a quick counter block, sampling cycle = 1 ms

• The counter starts with the parameterised starting value.
• If the comparison value is reached or exceeded:

• The counter jumps back to its starting value.
• The output bCount1(5)_Compare is set to TRUE.

• If there is a FALSE-TRUE edge is at the input bCountIn1(5)_ResetCompare, the output

bCountIn1(5)_Compare can be reset to FALSE.

• If there is a FALSE-TRUE edge at the input bCountIn1(5)_LoadStartValue, the current counter

content can be reset to the parameterised starting value.

Related topics:

Using DI1(5) and DI2(6) as digital inputs

( 306)

Using DI1(5) and DI2(6) as frequency inputs

( 307)

Internal interfaces | System block "LS_DigitalInput"

( 318)