Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

259

5

Motor control (MCTRL)

5.11

Encoder/feedback system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of the relevant parameters:

General procedure
(if the encoder is connected to the digital inputs DI1 and DI2)

1. Define the function of the digital inputs DI1 and DI2 in

C00115/1

.

2. Set the encoder increments in

C00420/1

.

3. Select "1: Encoder signal FreqIn12" in

C00495/1

.

4. Adapt the filter time of the speed measurement in

C00497/1

.

5. In the case of encoders with a very low resolution (number of increments < 120 increments):

Change the encoder evaluation procedure in

C00496

if necessary.

Parameter

Info

Lenze setting

Value Unit

C00495

Speed sensor selection

• Source of feedback signal for speed control.

No sensor

C00490

Position encoder selection

• Source of feedback signal for position control.

No sensor

C00254

Kp position controller

5.00 1/s

C00496

Encoder evaluation method ( 261)

Combined encoder method

C00586

Resp. to encoder open circuit

Encoder open-circuit monitoring ( 293)

Fault

C01206/1

Mounting direction: Motor

not inverted

C01206/2

Mounting direction: Position encoder

not inverted

Settings for encoder inputs DI1/DI2

C00115/1

Fct. DI 1/2 100kHz

• Function of the digital inputs DI1 and DI2

DI1(6)=In / DI2(7)=In

C00420/1

Encoder increments at FreqIn12

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

128 Incr./rev.

C00425/1

Encoder sample time FreqIn12

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

10 ms

C00497/1

Encoder filter time FreqIn12

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

1.0 ms

Settings for encoder inputs DI5/DI6

C00115/2

Fct. DI 5/6 10kHz

• Function of the digital inputs DI5 and DI6

DI1(6)=In / DI2(7)=In

C00420/2

Encoder increments at FreqIn67

• If the digital inputs DI5 and DI6 are used as

encoder inputs.

128 Incr./rev.

C00425/2

Encoder sample time FreqIn67

• If the digital inputs DI5 and DI6 are used as

encoder inputs.

• Only relevant for simple edge-counting

procedures (

C00496

= 3).

10 ms

C00497/2

Encoder filter time FreqIn67

• If the digital inputs DI5 and DI6 are used as

encoder inputs.

1.0 ms

Advertising