16

Parameter reference

16.2

Parameter list | C01245

1010

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01245

C01246

C01251

Parameter | Name:

C01245 | MCK: Target detection - positions

Data type: INTEGER_32

Index: 23330

d

= 5B22

h

Position settings for various MCK functions
Setting range

(min. value | unit | max. value)

0.0000

units

214748.3647

Subcodes

Lenze setting

Info

C01245/1

1.0000 units

MCK: Window target position

• Window around the target position for comparison

with the actual position to see whether the drive is in

target.

Target position monitoring

C01245/2

1.0000 units

MCK: Blocking zone Modulo

From version 06.00.00

Activation of the Modulo measuring system

C01245/3

0.0000 units

MCKI: Hysteresis position change

From version 12.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01246 | MCK: Select signal source

Data type: UNSIGNED_8

Index: 23329

d

= 5B21

h

From version 06.00.00

Selection of the touch probe signal source for reference search with touch probe detection

• If the reference signal is to follow a real touch probe, the

Touch-Probe-Interface

must be configured accordingly.

Homing

Selection list

0 No TP
4 TP-DigIn4
5 TP-DigIn5
6 TP-DigIn6

Subcodes

Lenze setting

Info

C01246/1

0: No TP

MCK: Ref. TP signal source

C01246/2

0: No TP

MCK: Set.Ref. signal source

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01251 | MCK: Acceleration stop

Data type: INTEGER_32

Index: 23324

d

= 5B1C

h

Acceleration parameter for stop

Stop

Setting range

(min. value | unit | max. value)

-214748.3647

units/s2

214748.3647

Subcodes

Lenze setting

Info

C01251/1

720.0000 units/s2

MCK: Stop: Decel.

• Deceleration for setpoint speed ramp-down to

standstill.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000