3 terminals 11, Terminals 11, 7technology applications – Lenze 8400 User Manual

Page 362

Advertising
background image

7

Technology applications

7.2

TA "Actuating drive speed"

362

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.3.3

Terminals 11

Connection

Assignment

Connection

Assignment

X41/DI1

LA_NCtrl.bSetSpeedCcw

DO1/DO2 is only available after respective change of the function

assignment in

C00116

.

X41/DI2

LA_NCtrl.bSetDCBrake

X42/DI3

LA_NCtrl.bMPotUp

X42/DO1

-

X42/DI4

LA_NCtrl.bMPotDown

X42/DO2

LA_NCtrl.bDriveReady

X43/DI5

-

X50/A1U

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C00011

)

X43/DI6

-

X50

GIO

GIO

GIO

DI1

DI5

n.c.

n.c.

n.c.

DI2

DI6

AR
A1U

GA

A1I

24O



+

…
„
‚
ƒ

X41

X42

X43







„

„

„

‚

‚

‚

…

…

…

ƒ

ƒ

ƒ

24O

24O

24O

+

+

+

+ 24 V

RFR

DI3

/DO1

DI4

/DO2

R

1k

... 10k

W

W

DC brake

Speed higher

Speed lower

Motor

potentiometer

Direction of rotation CCW

Controller enable

Speed setpoint

Advertising