18.1.22.5 Limit value monitoring

wMinDiameter and wMaxDiameter serve to define the limit values for the given diameter values. If

they are reached/exceeded, the corresponding ouput (bDMaxLimit/bDminLimit) is set to TRUE.

• The unfiltered diameter value dwOutDiameter and the filtered diameter value nDiameter_a are

limited.

• The limit values are entered in [mm].
• The hysteresis for resetting bDMaxLimit/bDminLimit is permanently set to 1 % of

wMaxDiameter.

• For parameter setting of further FBs, the value in wMinDiameter with regard to wMaxDiameter

is provided via the nDMin_a output.

18.1.22.6 Converting diameter in 1/D

For evaluating the material speed with 1/D (speed-controlled winder), the reciprocal value of the

reel diameter is provided via nReziprDiameter_a.

• This value refers to the limitation value wMinDiameter.

18.1.22.7 Physical state variables

The dwOutDiameter output provides the current diameter as physical quantity (1 LSB ≡ 1 m).
nNReel_v outputs the winding speed which results from the nMotorSpeedAct_v motor speed and

the current (wGearNum/wGearDenom) gearbox factor.
For supporting further functions (e.g. a traversing control), the winding speed is integrated

additionally.

• The angle of rotation is output via dnPos_p.
• By setting bResetPos to TRUE, the angle of rotation is reset.