2 configuring control inputs, 3 functional settings, Configuring control inputs – Lenze 8400 User Manual

Page 723: Functional settings, 15 parameter change-over

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

723

15

Parameter change-over

15.1

Configuring parameter change-over via the »Engineer« parameterisation dialog

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

15.1.2

Configuring control inputs

The three control inputs for parameter change-over can be configured via the following parameters:

Truth table for the selection of the value set to be used:

15.1.3

Functional settings

Parameter

Lenze setting

Info

Activate writing

(

C00621/123

)

0: Not connected

Selection of the signal source that activates writing

to the parameter list (for

Execute Mode

= "0: by

Execute").

Selection value set - 1

(

C00621/124

)

0: Not connected

Selection of the two signal sources for the binary-

coded selection of the value set 1 ... 4 to be used (see

following truth table).

Selection value set - 2

(

C00621/125

)

0: Not connected

Selection value set - 1

Selection value set - 2

Value set used

FALSE

FALSE

Value set 1

TRUE

FALSE

Value set 2

FALSE

TRUE

Value set 3

TRUE

TRUE

Value set 4