6.1.1.1

Using DI1(5) and DI2(6) as digital inputs

Function assignment 0: DI1(5)=In / DI2(6)=In
With this setting in

C00115

, the digital input terminals have been configured as "normal" digital

inputs.

• For each digital input, the debounce time (

C02830/1...6

) and the terminal polarity (

C00114

) can

be set individually.

• The current terminal level at the input of the internal processing function is shown in

C00443/1

in bit-coded form.

• The output level for the application is shown in

C00443/2

in bit-coded form.

Internal interfaces to the application

• Relevant outputs at the

LS_DigitalInput

system block:

Related topics:

Using DI1(5) and DI2(6) as frequency inputs

( 307)

Using DI1(5) as counting input

( 312)

Reconfiguring DI3(4) to output DO1(2)

( 316)

Internal interfaces | System block "LS_DigitalInput"

( 318)

Output

DIS code | data type

Value/meaning

bIn1 ... bIn6

C00443/2

| BOOL

Digital input DI1 ... DI6