18.1.33

L_ConvAP_1

This FB converts an analog value into a position.

Inputs

Outputs

Parameter

Function

Identifier

Data type

Information/possible settings

nIn_a

INT

Input value

• Scaling: 16384 ≡ 100 %

Identifier

Data type

Value/meaning

dnOut_p

DINT

Output signal

• Internal limitation to ±2

31

-1 (±2147483647)

Parameter

Possible settings

Info

C01045/1

-32767

32767 Counter

• Lenze setting: 1

C01045/2

-32767

32767 Denominator

• Lenze setting: 1

Note!