1 definition of the switching range, 2 dead time compensation, 1 definition of the switching range 6 – Lenze 8400 User Manual

Page 1416: 2 dead time compensation 6, 18 function library

Advertising
background image

18

Function library

18.1

Function blocks | L_SwitchPoint_1

1416

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.166.1 Definition of the switching range

Depending on the setting of the CenterMode (

C01064/x

), the switching range can be defined via a

start and end position or via the data of the center point/size of switching range:

[18-65] Definition of the switching range

18.1.166.2 Dead time compensation

The delay time of external switching elements can be compensated by setting the corresponding

delay time in

C01062/x

. From this input and the current speed ,the FB calculates a preliminary stop,

i.e. the bOut switching output is set correspondingly earlier.

[18-66] Dead time compensation

C01068/1

From version 12.00.00

Setting is bit coded:

Inversion of outputs

• Lenze setting: 0x0000

Bit 0 Inversion of output 1
Bit 1 Inversion of output 2
Bit 2 Inversion of output 3
Bit 3 Inversion of output 4
Bit 4 Reserved

...

Bit 15

Parameter

Possible settings

Info

dnSwitchPoint1_p

dn2ndPoint_Size1_p

dnSwitchPoint1_p

CenterMode = FALSE

dn2ndPoint_Size1_p

CenterMode = TRUE

Switching performance without dead time compensation

Switching performance with dead time compensation

Switching performance of the external switching element (with dead time)

C01062/1

: Dead time

dnSwitchPoint1_p

dn2ndPoint_Size1_p

bOut1*

bOut1

external component

velocity = nActSpeed_v

t

TRUE

TRUE

"ON"

FALSE

FALSE

"OFF"

Œ

0

1

2

CenterMode = FALSE

Advertising