CANopen option

11.8

Process data transfer

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Finally, the following parameters define the value that the process data words are to have when

they are decoupled:

[11-7] General signal flow in the event of a configured exception

Related topics:

Configuring exception handling of the output terminals

( 338)

Parameter

Info

Lenze setting

Value Unit

C00343/1

LP_CanIn1:wCtrl DiscVal

0

C00343/2...4

LP_CanIn1:wIn2...wIn4 DiscVal

0

C00343/5...8

LP_CanIn2:wIn1...wIn4 DiscVal

0

C00343/9...12

LP_CanIn3:wIn1...wIn4 DiscVal

0

C00344/1

LP_CanOut1:wState DiscVal

0

C00344/2...4

LP_CanOut1:wOut2...wOut4 DiscVal

0

C00344/5...8

LP_CanOut2:wOut1...wOut4 DiscVal

0

C00344/9...12

LP_CanOut3:wOut1...wOut4 DiscVal

0

Exception event (an error has occurred)

Application

C00342/1

C00343/1...12

CAN IN

C00344/1...12

CAN OUT