1 properties analog output – Metrohm tiamo 2.3 Patch 1 (process analysis) User Manual

Page 1635

Advertising
background image

■■■■■■■■■■■■■■■■■■■■■■

7 Instruments

tiamo 2.3 Patch 1 (for Process Analysis)

■■■■■■■■

1619

High level (100%)

Display of the highest analog output value with unit.

0% Mapping

Measured value to be used when the Low level (0%) is applied as out-
put value, with unit.

100% Mapping

Measured value to be used when the High level (100%) is applied as
output value, with unit.

Default value

Display of the default value the outputs takes directly after starting and
exiting the program. The default value is also set after an error or when
canceling the method.

[Edit]

Opens the dialog Properties Analog input in order to edit the selected
port.

[Port description]

Opens a menu in order to import or export port descriptions.

The menu [Port description] contains the following menu items:

Import

Import of a text file (TXT, CSV) containing the port description. Each line is inter-
preted as port description, spaces will be ignored.

Export

Export a text file containing the port descriptions of all digital inputs.

7.20.7.1

Properties Analog output

Dialogfenster Configuration

Devices [Edit] Properties... Properties - 'De-

vice type' - 'Device name'

Analog outputs [Edit] Properties Analog output

In the dialog window Properties Analog output the properties for the
individual analog outputs are set.

Port

Display of the internal designation for an analog output port of the type
AnOut_x_y_z, where x stands for the controller; y for the analog output
terminal and z for the output on this terminal.

Port description

Freely selectable designation for an analog output port. This designation is
used in the program to actuate the port.

Advertising