Standard Data Types
All data types described by standard IEC61131-3 are supported by »PLC Designer«. See
here the following
• BOOL
• Integer Data Types
• REAL / LREAL
• STRING
• WSTRING
• Time Data Types
Notice that there are also some norm-extending data types and that you can also
define types on your own (user defined data types).

bool
BOOL type variables may be given the values TRUE (1) and FALSE (0). 8 bits of memory
space will be reserved.
See also: BOOL constants (Operands)

Integer Data Types
See below a list of all available integer data types. Each of the different number types
covers a different range of values. The following range limitations apply to the integer
data types:

Type

Lower limit

Upper limit

Memory space

BYTE

0

255

8 Bit

WORD

0

65535

16 Bit

DWORD

0

4294967295

32 Bit

LWORD

0

2

64-1

64 Bit

SINT

-128

127

8 Bit

USINT

0

255

8 Bit

INT

-32768

32767

16 Bit

UINT

0

65535

16 Bit

DINT

-2147483648

2147483647

32 Bit

UDINT

0

4294967295

32 Bit

LINT

-2

63

2

63-1

64 Bit

ULINT

0

2

64-1

64 Bit


As a result when larger types are converted to smaller types, information may be lost.
See also: Number constants (Operands)