L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 793

Advertising
background image

L-force | PLC Designer

General Editors

DMS 4.1 EN 03/2011 TD29

791

Variable Settings
See in the following a description of the trace configuration dialog for variable
settings.

Abb. 433 Trace Configuration, Variable Settings

For the trace record you must define the variables to be "traced" and to be displayed in
the record coordinate system. In order to add a variable to the record use button New
Variable
(bottom part of the window) in the left part of the Trace Configuration
window. In the right part of the window now the Variable Settings dialog will appear
and at the same time an empty variable entry will be added in the record tree. Define
the variable:
Variable: Enter here the name (path) of the variable to be traced. Beside of data
variables it is possible to trace the content of pointers, properties, references or array
elements. The input assistant (

) can be used in order to get a valid entry. Check

resp. edit the current configuration settings (see below). The variable will be
immediately entered in the trace tree. To modify the variable settings later, just select
the variable entry in the trace tree and use the Variable Settings dialog again.
Graph color: From the given color selection list choose a color in which the trace curve
for the variable should be displayed.