Select the Add tappet tool of the toolbox to add a new tappet action. You can indicate
its appropriate position by a click on the left mouse button within the desired track.
The new tappet will be inserted and instead of the Add tappet tool and now the Select
tool will automatically be activated. After selecting a tappet by a click in its center you
may move the tappet while keeping the mouse button pressed or delete the tappet
event
by pressing the delete key.

You can assign different events ("switch on", "switch off", "invert", "none") to the pass
of a tappet in either positive (ascending master values) or negative direction. Have a
look at the table beyond for all possible combinations. All attributes of tappets of one
track, that is of the same identification number, refer to the same tappet bit, that is a
variable of boolean type. By default, a cam has the attributes "switch on" on positive

pass and "switch off" on negative pass

, so that the boolean variable will be set to

TRUE on positive pass and set to FALSE on negative pass. The event "invert" will negate
the value of the boolean variable, whereas "none" has no impact at all. You may

change the attributes of the cam each by a click on the related end of the cross

to

turn it on or off.