L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 288

Advertising
background image

L-force | PLC Designer

Menu Commands sorted by Categories

286

DMS 4.1 EN 03/2011 TD29

In case of an Udp block driver you may edit its Name and specify the IP Address, if you
want to change the default router. Further you may indicate the Network Mask, the
Port Index (for selecting the port number of the »PLC Designer« gateway; the Port
Index ranges from 0 to 3, where the index 0 corresponds to the port number 1740 and
the Index 3 to 1743). Entering a Ppp Remote Address establishes a logical point to
point connection between the Udp interface and the node indicated by this address.
The consequence is that the Udp interface will communicate with this node exclusively
and no more broadcasts will be sent within this network.

Abb. 108 Dialog Gateway - Block drivers (Udp)