Common.canbus configuration, L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 881

Advertising
background image

L-force | PLC Designer

Device Editors

DMS 4.1 EN 03/2011 TD29

879

Double Node ID: This box contains a list of all devices carrying identical IDs. You may
assign new node IDs by editing the fields in column "Node ID".
Wrong Cob Id (only enabled PDO are shown). Bit 31 in formula is ignored:
Unfortunately the Cob Ids created automatically out of the device description file
might not be correct. All incorrect entries are listed with their related device names,
node IDs and indices. There are three possibilities to correct the COB IDs:
• Either you edit the displayed formula in such way that a valid COB ID will result.

The editing may be done directly in the corresponding table field.

• Or you adopt the "Automatic suggestion" given in the last column of the table by

clicking on it.

• Or you adopt all automatically created suggestions (displayed in the last column) at

once by clicking on Use suggestion for all.

Corrected items will be removed from the list automatically.

Common.CANbus Configuration
This dialog will only be available in the device editor for a CANopen Manager device, if
option 'Show generic device configuration views' is activated. It corresponds to the
Configuration dialog provided by the Device editor for other device modules.

Abb. 483 Common.CANbus Configuration dialog

The device-specific parameters defined by the manufacturer in the device description
file will be listed in a table and might be edited there if allowed by the description file.

Advertising