L-force | PLC Designer

Lenze Specific Functions

38

DMS 4.1 EN 03/2011 TD29

Inputs (VAR_IN)

Designator / Data type

Info / Setting options

xExecute

When a new positive edge is set, a new measurement is started. All
outputs of the block are reset to the initial values.

xWindowsOnly

Activation of window evaluation: All measured values outside the
defined window are suppressed.

wExternalDelayCompensation Manual compensation for the propagation times of the axis positions

on the respective fieldbus. The delay time is entered in [µs].

lrFirstWindowPosition

Lower limit of the window in SoftMotion units [SM units]

lrLastWindowPosition

Upper limit of window in SoftMotion units [SM units]

TriggerInput

See below description: L_SMC_Trigger_REF


TriggerInput / L_SMC_Trigger_REF:

Variable

Type

Initial
value

Description

TouchProbeSelect

BYTE

1

Selection of TP1 or TP2
1: TP_Channel1 -> DigIn 1
2: TP_Channel2 -> DigIn 2

TouchProbeMode

BYTE

1

Selection of operating mode
1: Single measurement; Execute edge activates
the function until Done = 1 (TRUE) or abort by
means of FB L_SMC_AbortTrigger.
2: Continuous measurement; Positive execute
edge activates the function until negative
execute edge (Execute = FALSE) or abort by
means of FB L_SMC_AbortTrigger.

TouchProbeSignal

BYTE

1

Selection of zero pulse or digital input
1: Digital input

TouchProbeEdge

BYTE

1

Configuration of edge evaluation
1: Triggering with positive edge
2: Triggering with negative edge
3: Triggering with positive or negative edge
(logic in the FB)