L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 672

Advertising
background image

L-force | PLC Designer

General Editors

670

DMS 4.1 EN 03/2011 TD29

Fix target device address: If this option is activated, the communication will be done
via the specified address. So enter the address of the data source device. Enter here the
address of the desired data source device, either manually or using the automatic
presetting by 'From Device' (see above). Example Example, Entering the address of the
data source device

.

Search for target device: Alternatively to the use of a fix address (see above) this
option can be activated, if a currently available device should be searched according to
certain search criteria. Activate the desired criteria by setting a checkmark in the
option box:
Node name: Node name, e.g. WST06
Target-Type: Type number of the device, e.g. "4096"
Target-Id: e.g. "0000 0001"
Target-Version: e.g. "1.0.0.0"
Network location: Chose where to look for the target device from the selection list:
• Direct child of the data server plc:

In this case the runtime system running the data server must implement a router
component that is accessible from IEC. In this case the device description file of the
device where the data server is located on must additionally include the
compilerdefine CMPROUTER_AVAILABLE to signal that the router library can be
used.

• Direct child of node with address:

Insert the address of the father in the edit field appearing to the right.