Function block l_smc_readaxiserror, L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 37

Advertising
background image

L-force | PLC Designer

Lenze Specific Functions

DMS 4.1 EN 03/2011 TD29

35

Function block L_SMC_ReadAxisError
Function library: L_SM3_DriveUtil.lib
This block serves to read the error code of a motion drive.


Inputs (VAR_IN)

Designator / Data type

Info / Setting options

Axis / AXIS_REF

Here, the axis structure for which the code is to be read is transferred.

xEnable / BOOL

Activates the function.


Outputs (VAR_OUT)

Designator / Data type

Value / Meaning

xValid / BOOL

Request has been executed

xBusy / BOOL

Request has been started

xError / BOOL

Request executed with error

wErrorID / WORD

Error number for this command to be executed, not the error number of the
drive

xAxisError / BOOL

Drive has signalled an error

dwAxisErrorID / DWORD

Read error number of the drive


Error messages
The following error messages have been stored:

Error number [hex]

Description

SMC_RP_PARAM_UNKNOWN:=130 Unknown code

SMC_RP_REQUESTING_ERROR:=131 Read request has been aborted, e.g. because the drive did not

respond in the prescribed time.

For the meaning of the drive error numbers, please refer to the drive documentation.

Advertising