L-force | PLC Designer

General Editors

608

DMS 4.1 EN 03/2011 TD29

See also:
• Positioning
• Switch functionality (H-function)
• Additional function (M-function)
• Usage of variables
• Circular interpolation
• Ellipse interpolation
• Spline interpolation
• Conditional jumps
• Change variable values

Word identifiers :

Letter

Function

A

Target position of additional spline axis A.

B

Target position of additional spline axis B.

C

Target position of additional spline axis C.

D

Tool radius (for correction G40-42 resp. for 'Round of Path' G50-51)
resp. variable value (G36/G37)

E

Max. acceleration (>0) / deceleration (<0) [path-units/sec

2

]

F( feed)

Velocity [path-units/sec]

G (geometry)

Positioning command

H

Switch on switch point (>0) / switch off (<0)

I

X-coordinate of the circle/ellipse center (G02/G03/G08/G09)
or X-coordinate of the parabel-tangent-intersection-point

J

Y-coordinate of the circle/ellipse center (G02/G03/G08/G09)
or Y-coordinate of the parabel-tangent-intersection-point

K

Direction of the ellipse main axis in mathematical sense (0° O, 90° N,...)
resp. jump condition (G20) resp. dT1 parameter value (M-function)
or Z-coordinate of the circle center (G02/G03 in 3D mode only)

L

Absolute switch position "H"), measured from start position (>0)
resp. end position (<0) of the path object,
resp. jump condition (G20)
resp. dT2 parameter value (M-function)

M (machine)

Additional option, M-option (M-function)

O

Relative switch ( "H") position [0..1]
resp. the variable to be changed (G36/G37)
or M-parameter data structure (M)

P

Target position of the additional linear axis P