To set up a trace use the context menu in the right part of the trace window ...

1.

New Variable...: dialog to add a variable and set some display parameters (color,
graph type etc.).

2.

Delete Variable: to delete the selected variables.

3.

Visible: to set a selected variable visible.

4.

Appearance...: dialog to determine the appearance of the graph (This command is
grayed as long as no configuration is loaded).

5.

Configuration...: dialog for the definition of the trace (conditions, curve type etc.,
and once again appearance of the graphs) with its particular trace variables.

A trace configuration can be stored to an external file *.trace and be reloaded to the
trace window.
downloaded to the target system.

Trace editor in online mode
To perform a trace record viewing the code generated for the trace must explicitly
loaded to the target system with the menu command Download.
The Trace menu provides additional commands for working in the currently displayed
trace graphs.

New Variable...
The Trace Configuration dialog with the Variable Settings dialog opens when using
command New Variable... in the context menu of the trace tree window in the Trace
Editor.

Abb. 428 Trace Configuration dialog