Letter Function

G42

Start the tool radius correction to the right of the workpiece

G50

End of RoundPath/SmoothPath function

G51

Start the SmoothPath function

G52

Start the RoundPath function

G53

End the shift coordinate function.

G54

Set offset of all following coordinates to the specified position

G55

Add the specified position to the current offset.

G56

Set the offset such that the current position equals the specified position

G60

End of the avoid-loop function

G61

Start of the avoid-loop function

G75

Time synchronisation with interpolator

G90

Start interpreting the following coordinate values (for X/Y/Z/P-W/A/B/C) as absolute values
(default)

G91

Start interpreting the following coordinate values (for X/Y/Z/P-W/A/B/C) as relative values

G92

Setting the position without move

G98

Start interpreting the following coordinate values of I/J/K as absolute values

G99

Start interpreting the following coordinate values of I/J/K as values relative to the starting point
(standard)

Please regard that the library "SM3_CNC " must be included to enable an error-free
compilation of the project.

Positioning
Command G0, G92
These commands are used for changing interpolator positions.
In case of G0 the changing is done by moving on a line to the next position. In
contrastto G1 the G0 elements aren't modulated with path-preprocessors like tool
radius, smooth path or round path correction.
With G92 the position of the interpolator is set by jump. The consequence is, that
these jumps are executed on the axes, except when programming features like
MC_ControlAxisByPos.bAvoidGaps:=TRUE prevent this. „smc_controlaxisbypos“. If G92
is applied in a CNC programm before the frirst positioning element, then it can have
the designed use of setting the start position.