Lenze function blocks and functions, Library: l_plcloggingaccess.lib, Function l_addlog - creating logbook entry – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 25: L-force | plc designer

Advertising
background image

L-force | PLC Designer

Lenze Specific Functions

DMS 4.1 EN 03/2011 TD29

23

2.1

Lenze Function Blocks and Functions

2.1.1

Library: L_PLCLoggingAccess.lib

Function L_AddLog - Creating logbook entry
Function library: L_PLCLoggingAccess.lib
This function makes it possible to make an entry in the logbook of the L-force
controller. It supplies the return value TRUE when the entry has been made.


Inputs

Designator / Data type

Info / Setting options

eSeverity / L_TSeverity

Logging severity - Risk of the error

L_FatalError

L_Error, L_Warning

L_Information

The Enum parameter eSeverity (IEC_INT) is sent as the severity (BYTE) to
Add2Log.

eFacility / L_TFacility

Logging facility: - Area out of which the error is reported

L_PLC_USER_LOG_SCOPE1

L_PLC_USER_LOG_SCOPE2

L_PLC_USER_LOG_SCOPE3

The Enum parameter eFacility (IEC_INT) is sent as the facility (WORD) to
Add2Log.

sLogPayLoad / STRING(80)

Logbook entry

The Ansi string from "sLogPayLoad" is sent as a 1-byte string parameter to
Add2Log. ("hs", SLOGPAYLOAD)

Advertising