13.19.2

Web-Visualization Editor
The WebVisualization object inserted below the Visualization Manager object
contains the settings for the Web-Visualization. These can be modified in the editor
window which opens on a double-click on the object:

Abb. 463 Web-Visualization Editor

For some basics and the preconditions for running a Web-Visualization see the Web-
Visualization help page.

Start Visualization: Name of the visualization to be displayed automatically when the
Web-Visualization gets started. By default "Visualization" is entered here. To set
another visualization you might use the Input Assistant offering the currently available
visualizations.
Name of .htm file: Name of the basic HTML-page of the visualizaton. Must also be
entered as address in the web browser; example: http://localhost:8080/webvisu.htm
Updaterate (ms): Update rate within the web browser, in milliseconds
Default Communication Buffer Size: in Bytes, defines the maximum available buffer
for the data transfer between web client and web browser.
Best Fit:
Best fit in online mode: If this option is activated, the size of the visualization will be
adapted to the size of the web-browser window.
Use specified client size: If this option is activated, the size of the visualization will be
defined by the following settings:
Client width: Width in pixels
Client height: Height in pixels