L-force | PLC Designer

Menu Commands sorted by Categories

DMS 4.1 EN 03/2011 TD29

397

Another version of the application is already available on the controller in not

running mode. You will be asked whether that should be replaced via a dialog box
with the following text: "Unknown version of Application '<Application>' on target:
Do you want to perform a download and replace the application?". The Details
button in this dialog provides some information (Project name, Last modification,
IDE version, Author, Description) on the application in the IDE ( integrated
development environment = programming system) confronted to that on the
controller.

A version of the application is already available on the controller in RUN mode. You

will be asked whether you really want to log in regardless and overwrite the
currently running application. For this purpose a dialog box with the following text
will open: "Warning: An unknown version of the application '<application name>'
is currently in RUN mode on the PLC. However, do you want to download the latest
code and replace the existing application?" The Details button in this dialog
provides information on the application version in the programming system
confronted to that on the controller.

The application is already available on the controller but has been modified since

the last download. You will be asked whether an online change should be done, or
a login with loading the complete application code, or a login with out any change
of the running application. For this purpose a dialog box with the following text
will open: "The code has been changed since the last download. What do you want
to do? - Login with online change. - Login with download. - Login without any
change." The Details button in the dialog provides information on the modified
application in the programming system confronted to the previous version on the
controller.