12.13.28 Set/Reset

Symbol:
Shortcut: <Ctrl> + <M>
This command (category 'FBD / LD / IL') is used in FBD or LD to define boolean outputs
resp. coils as "Set" or "Reset" outputs resp. coils. It is not available in the IL editor,
where the corresponding modifiers have to be used appropriately.
With multiple executions of the command, the output will alternate between set,
reset, and normal output.

Note: Concerning the view options for the components of a LD / FBD network notice
the settings in the 'FBD/LD and IL editor Options'.

12.13.29 Set output connection

Symbol:
Shortcut: <Ctrl> + <W>
This command (category 'FBD / LD / IL') can be used in FBD or LD with boxes which
have multiple outputs to determine that output which should be connected to the
network processing line.
This is an extension compared to »PLC Designer« V2.3 where only the uppermost
output can be connected to the processing line.
Notice the shift of the output assignments in case of changing the output connection.

Abb. 117 Example: set output connection at o3

Note: Concerning the view options for the components of a LD / FBD network notice
the settings in the 'FBD/LD and IL editor Options'.